Console FZV JU913S-400
Load test and design calculation for load has been carried out 2/3 out from the wall mount on the profile
Watch this product and we will notify you once it is back in stock.
Console FZV JU913S-400
Load test and design calculation for load has been carried out 2/3 out from the wall mount on the profile
Console FZV JU913S-400
Console FZV
Loads:
According to SS-EN1993-1-1:2005/AC:2009, EUROCODE 3
Dimensioning in safety class 3 for static load.
According to SS-EN 12236 with safety factor 3
Test and calculation point:
Load test and design calculation for load has been carried out 2/3 out from the wall mount on the profile.
Specifications:
- Material: EN 10025-2 S235JR
- Length: 400 mm
- Height: 200mm
- Wall plate: 40x5mm
- Hole in wall plate: Ø 13mm c/c 160mm
- Hole in profile arm: Round hole = Ø 11mm, c/c 25mm, Slotted hole = 11x36mm, c/c 50mm
- Hot-dip galvanizing: SS EN ISO 1461:2009
- Load according to SS-EN 12236: 2.16
- Load according to EK kN: 1.15